LLExec RTX: Difference between revisions
Jump to navigation
Jump to search
(Created page with "=LLExec for RTX (32bit) usage instructions= ==Prerequisites== * RTX must be alredy correctly installed and configured on the Windows system * RTX must have the virtual network...") |
No edit summary |
||
Line 25: | Line 25: | ||
==Execution== | ==Execution== | ||
* Execute '''LLExec_RTX.bat''' to launch LLExec | * Execute '''LLExec_RTX.bat''' to launch LLExec | ||
** On the first execution, LLExec will save a '''HardwareID.txt''' file on the disk and quit immediately; please send this file to ''support@axelsw.it'' and you will receive back a license file named '''LLExecRTX.key''', to be placed in the same folder | |||
* Execute '''socat_LLExec.bat''' to allow LogicLab connections from the LAN | * Execute '''socat_LLExec.bat''' to allow LogicLab connections from the LAN | ||
* | |||
==LogicLab usage== | |||
* Execute LogicLab | |||
* Create a new project using the '''LLExec PLC runtime (RTX)''' target | |||
* Configure the GDB connection using the normal IP address of the Windows side, port 5000 | |||
[[Category:LLExec]] | [[Category:LLExec]] |
Revision as of 14:39, 5 October 2017
LLExec for RTX (32bit) usage instructions
Prerequisites
- RTX must be alredy correctly installed and configured on the Windows system
- RTX must have the virtual network interface (between RTX and Windows) correctly configured
- RTX must have one physical network interface correctly assigned and configured (for EtherCAT master only)
Downloads
- Get the latest version of LogicLab Automation suite setup from Axel website (public download area)
- Get the latest version of LLExec (x86 Windows) setup from Axel website (public download area)
- Get the latest version of LLExec for RTX binaries from Axel website (private customer area)
- Get the latest version of socat binaries from Axel website (private customer area)
Installation
- Install the LogicLab Automation suite using the setup
- Install the LLExec (x86 Windows) using the setup
- Unzip the LLExec archive where you want
- If you DO NOT NEED EtherCAT master functionality:
- edit RegisterRtxDll.bat and remove the registration of LLXPlugin_EtherCAT_RTX.rtdll and RTXFilterDriver.rtdll
- edit LLExec_RTX.conf and remove the line with LLXPlugin_EtherCAT_RTX.rtdll
- Execute RegisterRtxDll.bat to register the .rtdll components in the system
- Get the latest version of socat binaries from Axel website
- Unzip the socat archive where you want
- If the IP address of the RTX side of the virtual network interface is different from 192.168.1.1, please edit the socat_LLExec.bat
Execution
- Execute LLExec_RTX.bat to launch LLExec
- On the first execution, LLExec will save a HardwareID.txt file on the disk and quit immediately; please send this file to support@axelsw.it and you will receive back a license file named LLExecRTX.key, to be placed in the same folder
- Execute socat_LLExec.bat to allow LogicLab connections from the LAN
LogicLab usage
- Execute LogicLab
- Create a new project using the LLExec PLC runtime (RTX) target
- Configure the GDB connection using the normal IP address of the Windows side, port 5000